Problems with UHT During the processing of
non-Dutch coco it has the tendency to create small cracked coco particles,
which are later hard to dissolve, and contains spore formers. When coco particles are not fully dissolved or hydrated, it can lock spore formers into a fat/oil shell inside the coco particle. See drawing. Thermo
spore What is happening: 2) The particle is not
hydrated completely. 3) The Coco is blended
into your product. 4) The oil/fat from your
product is immediately attaching to the coco and enclosing the thermo former
in an air pocket. 5) Due to the fat/oil
shell around the coco particle, further hydration is minimal. 6) Now this particle is
being processed. Briefly,
we can state that the UHT treatment cannot be sufficient enough since the
thermo former is insulated by the air pocket and can release its heat to the
particle itself. This could result in suspect product or product non-sterility. To reduce this problem it is key that the coco particle is fully hydrated before it is mixed with the production batch. If the formulation and further procedure allows it, adding the butter, fat and/or oil could be done in phases. For example 1/3 before the coco is dosed into the blend and 2/3 after the coco.
|
Last modified: Monday, January 17, 2005 14:51:40 1999-2005 Copy right © ASEP-TECH USA LLC. ALL RIGHTS RESERVED. |